Voltage divider workbench

Check what happens to your output when you connect a load. Then find standard resistor values that fit your voltage and current budget.

0.1–24 V DC nominal

Circuit inputs

Enter 4.7k, 4k7, or 4700 for 4.7 kΩ.

Tolerances

Output under load

3.125 V

208.3 mV drop from the open circuit

Open-circuit output
3.333 V
Worst-case output range
3.103–3.146 V
R1 goes from the supply to the output. R2 and the 100 kΩ load both go from the output to ground.
Source draw
187.5 µA
Load draw
31.25 µA
Output impedance
6.667 kΩ

Sweep the load

Lower load resistance draws more current and pulls the output down.

100 kΩ → 3.125 V

Output voltage across a logarithmic load scale of 1 Ω to 10 MΩ. The dashed line marks the open-circuit output.
Current and resistor dissipation
R2 branch current
156.3 µA
R1 power
351.6 µW
R2 power
488.3 µW
Load power
97.66 µW
Worst-case source draw
189.2 µA

Power readings use nominal values. The voltage range and maximum draw include the specified tolerances for the supply, both resistors, and the load.

Find standard resistor pairs

Compare E24 and E96 values from 100 Ω to 1 MΩ. Set a current ceiling and try any result on the workbench.

5 V supply · 100 kΩ load ±0% · resistors ±1% · supply ±0%

    The current ceiling includes the selected tolerances. Resistance values and tolerance are independent inputs.

    Why does the output change?

    The load sits in parallel with the bottom resistor, reducing that leg’s effective resistance. That changes the ratio even when R1, R2, and the supply stay the same. Follow a worked 5 V example in the loading guide.

    Read the loaded voltage divider guide